Ir3 flame detector pdf file

The flame detector is connected to the fire panel with 3 or 4 core cables, i. Fsl100 series flame detectors fsl100 flame detector types fsl100uv, fsl100uvir and fsl100ir3. All utilize sophisticated sensing and signal analysis to detect fires quickly while also rejecting false alarms. This guide describes the sharpeye model 40 40i triple ir ir3 flame detector and its features and provides instructions on how to install, operate, and maintain the detector. Flame detector flameproof ex d, ir3 flame detectors. User manual fixed gas detectors, portable gas detectors. Taking the field of view range into account will help determine how many. The fsl100 may be small and lightweight for easy installation but it is designed to work in tough indooroutdoor environments, as well as potentially explosive atmospheres. It is sensitive to low frequency, flickering infrared.

The intelligent ir3 flame detector is designed to protect areas where open flaming fires may. Type, batch or serial number or any other element allowing identification of the. Addresses a wide range of fire protection applications both indoors and outdoors. Choice of red or white housings range 110 ft 35 m ir3, 25 m80 ft uv, uvir alarming within 10 seconds to a 1 ft20. Flameproof, ir3 flame sensor stainless steel flameproof, ir3 flame sensor flameproof, ir3 flame sensor for high ambient temperatures part number 016589 supply voltage 14 to 30 vdc. The fguard ir3hd fg1ir3hd will detect fires and explosions extremely fast allowing preventative action to be initiated rapidly and minimize the consequences. Triple ir ir3 flame detector superior performance, reliability and immunity to false alarms the new 4040i, a multi spectrum based on three ir bands ir3, detects fuel and gas fires at long distances with the highest immunity to false alarms. Leave a comment on ir3 flame detector pdf ir3 flame detector. The 4040i is the most durable and weather resistant flame detector currently on the market.

The signals from both sensors are analyzed for frequency, intensity, and duration. Flame detection technologies effectively recognize a flame at different distances. Conventional, exd, spectrex sharpeye ir3 flame detector. The sensors must exceed their alarm threshold to initiate a fire alarm. No part of the hardware, software or documentation. These flame detectors give high immunity to false flame sources. Sharpeye 20 user and maintenance manual pdf download. A wide variety of ir3 flame detector options are available to you, there are 60 suppliers who sells ir3 flame detector on, mainly located in asia. Ipesir3 flame detector operating manual esp safety inc. The range consists of uv, uv ir and ir3 flame detectors. Sharpeye mini ir3 flame detector manual tm 787100, rev. The range consists of uv, uvir and ir3 flame detectors.

It is important to utilize a detector that can operate within your required detection range. The ir3 flame detector is sensitive to low frequency. The intelligent ir3 flame detector is designed to protect areas where open flaming fires may be expected. This guide describes the sharpeye model 2020mi mini triple ir ir3 flame detector and its features, and provides instructions on how to install, operate, and maintain the detector. Ir3 meets fm us and canada certifications and requirements for hazardous location classification.

The uvir flame detector senses radiant energy in the short wave sections of both the ultraviolet and infrared portions of the electromagnetic spectrum. Flame detector is designed to protect areas where open fires may be expected and detects almost all flames, including hydrocarbon fires with 4. Rosemount does not assume any liability arising out of the application or any use of any product or circuit described herein. Ipesir3 flame detector operating manual page 5 of 32 4. They can operate on a conventional 2wire 1428 vdc fire systems or 420ma process control systems.

Simultaneous detection of radiant energy by both the. Honeywell fsl100ir3 technical handbook pdf download. The spectrex 4040i is one of the most durable and weather resistant flame detector on the market. Ir3 flame detector ir3 flame detector intrisically safe is ir3 flame detector extended temperature ir3 flame detector flameproof exd ir3 flame detector flameproof exd, extended temperature ir3 flame detector stainless steel ir3 flame detector stainless steel flameproof exd 16589 16579 16289 16519 16219 16509 16549. This guide describes the sharpeye model 4040i triple ir ir3 flame detector and its features and provides instructions on how to install, operate, and maintain the detector. A more exact relation valid when the distance between the flame and the flame detector is small between the radiation density, eat the detector and the distance, dbetween the detector and a flame of effective radius. Single ir flame detector hydrocarbonbased flame detection.

Jul 02, 2019 ir3 flame detector pdf ir3 flame detector sensitivity according to en class 1. Ir3 flame detector pdf ir3 flame detector sensitivity according to en class 1. Mar 19, 2020 ir3 flame detector sensitivity according to en class 1. Fsl100 series flame detectors uv, uvir, ir3 honeywell analytics. The referenced flame is moved to 50% of the maximum onaxis detection distance and then moved offaxis horizontally and vertically to the limit of detection. Triple ir ir3 flame detector dimensions mm also available. Triple ir ir3 flame detector model 2020si users and maintenance manual tm 784100, rev. With 3 versions to cover a wide range of flaming fires. Ir3 flame detector senseware the flame detector company. Jan 17, 2019 the intelligent ir3 flame detector is designed to protect areas where open flaming fires may be expected. Apr 25, 2020 ir3 flame detector sensitivity according to en class 1. Single ir flame detector 3600r sierra monitors 3600r flame detector monitors hydrocarbonbased fuel and gas fires using advanced flame analysis tools. The triple ir flame detector uses an additional alarm criterion. They have internal selftest sources that check the detector s operation when remotely instructed.

This user guide should be read carefully by all individuals who have or will have responsibility for using, maintaining, or servicing the product. Ultraviolet uv, ultravioletinfrared uvir and triple infrared ir3. Sharpeyetm ir3 flame detector manual tm 2020i, rev. Triple spectrum design for long distance detection and high false alarm. Relay contacts are also available for fire and fault signals.

The spectrex 4040i triple ir ir3 flame detector can detect fuel and gas fires from a long distance, and with the highest immunity to false alarms. They have internal selftest sources that check the detectors operation when remotely instructed. Tripleir3 flame detector user and maintenance manual. Detection within 40 milliseconds of fireballs or explosions standard fire is detected within 1. Chapter 1, introduction, provides a general introduction and overview of the product. The detector has three sensors which respond to different ir wavelengths to discriminate between flames and spurious sources of radiation. Triple ir ir3 flame detector users and maintenance manual. Tripleir3 flame detector triple irir3 model zt500ex user and maintenance manual 47153, rev. The 3600m uses infrared ir technology, a reliable design that provides early warning of flaming fires and immunity to false alarms from ir sources such as sunlight and ir projectors. The area in front of a flame detector, where a standardized flame can be detected and which is specified by distance and angle off the central axis, is the field of view. This user guide should be read carefully by all individuals who have or will have responsibility for using, maintaining, or. Flame detector is sensitive to flickering, low frequency 1 15hz. Its new features include a heated window, to eliminate condensation and icing. Optical flame detectors come with a field of view range, similar to the lens on a camera.

The 4040i ir3 can detect a small 0,1m2 gasoline or heptane pan fire at 65m in less than 5 seconds. Aug 21, 2019 ir3 flame detector sensitivity according to en class 1. Triple ir ir3 flame detector model 2020i users and maintenance manual tm 2020i, rev. The ir3 flame detector is designed for harsh environments in indoor applications. The information in this document has been carefully checked and is believed to be entirely reliable with all of the necessary information included. The triple infrared ir3 flame detector is designed to protect areas where open fires may be expected. It has applications in a wide range of industrial and commercial facilities, where the threat of accidental fire involves hydrocarbon fuels such as gasoline, hydraulic fluid, paint, various solvents, aviation fuel, natural gas, propane, acetylene, etc. A range of middle market optical flame detectors joining the ha fsx high end products. This guide includes the following chapters and appendices. Introduction the fguardir3 flame detector provides ultrafast response, high performance and reliable detection of all types of hydrocarbon fires visible and nonvisible. These flame detectors give excellent immunity to false flame sources both indoors or out.

Fire alarm systems 016519 flame detector flameproof ex d, ir3 016519 flame detector flameproof ex d, ir3. The flamegard ir3 flame detector has been designed as a multipurpose flame detector. Radiationtype flame detectors collect radiation from the area. Ir3 flame detector sensitivity according to en class 1. Class i, division i, group b, c and d and t4 case design accords with fm 3600 and fm 3615. Approved class i groups b, c, d class ii groups e, f, g s. Flame detector ipes ir3 the stateoftheart multispectral infrared technology of esp safetys model ipesir3 flame detector affords the highest level of sensitivity in detecting. The glt exports optical flame detector described in this document is the property of glt exports inc. Fsl100 series flame detectors uv, uvir, ir3 notifier fire systems. The 3600lb uses a combination of ultraviolet uv and infrared ir sensor technology. The senseware ir3 flame detectors utilizes a microprocessor for sophisticated electronic signal analysis.